Baxi have one of the best reputations in the market for delivering top quality boilers.
Should you need professional help with your broken boiler, then simply use one of our contact forms and we will connect you with the best heating engineers local to you.
Baxi Platinum Error Codes
Listed below are the most common error codes that you might see on your Baxi Platinum combi range of boiler.
Fault Code | Possible Cause |
---|---|
E20 | Central heating NTC error |
E28 | Error with the NTC flue. Possible air pressure switch error. Blocked flue or condensate or wing fault |
E50 | Hot water NTC error |
E110 | Thermostat operated safety |
E119 | Water pressure switch error – Not operated. |
E125 | Primary circuit error circulation fault |
E130 | FLue NTC Operation error |
E133 | Gas supply Error or flame failure |
E160 | Fan Error / Fan Wiring Error |
E193 | Pre-circulation error |
Baxi EcoBlue Error Codes
Fault Code | Possible Cause |
---|---|
110 | Overheated – try bleeding your radiators |
117 | Water pressure too high |
118 | Water pressure too low |
125 | Water circulation fault |
133 | Safety time to establish flame exceeded |
E10 | Outdoor Sensor Error |
E20 | Central Heating Thermistor Sensor Fault |
E28 | Flue Thermistor Fault |
E54 | HW Flow Sensor Fault |
E78 | Water Pressure Sensor Fault |
E100 | Internal Clock Time Error on PCB |
E109 | Poor Circulation |
110 | Overheat – try bleeding your radiators |
111 | Maximum Limit of Flow Temperature |
117 | Water pressure too high |
118 | Water pressure too low |
119 | System Pressure Low |
125 | Water circulation fault |
127 | Legionella Protection Temperature not reached |
128 | Loss of flame during operation |
133 | Safety time to establish flame exceeded |
153 | Forced reset unit unlocked |
160 | Fan Fault |
162 | Air pressure switch error |
164 | Heating flow switch error (Ireland) Pressure Sensor Error (UK) |
166 | Air Pressure Switch Fault |
270 | Dry Fire |
432 | Earth connector error |
433 | Heat exchanger temperature exceeded (greater than 95 degrees) |
Baxi 200 / 400 Combi Gas Boiler Error Codes
Fault Code | Possible Cause |
---|---|
H.01 – .00 | Loss of communication between gas valve and boiler board. Possible faul in air or gas unit / loose connection to gas valve |
H.01 – .05 | Difference between the flow and return temperature has exceeded / sensor error / no or insufficient circulation |
H.01 – .08 | Sensor fault / Flow temperature increasing to fast in heating mode / no or insufficient circulation |
H.01 – .14 | Maximum flow temperature value exceeded / no or insufficient circulation / no or insufficient circulation ( temporary fault ) |
H.01 – .18 | No circulation of water. No or insufficient circulation. Sensor error. |
H.01 – .21 | Temporary error- Flow temperature increasing too fast in DHW mode. No or insufficient circulation. Sensor error. |
H.02 – .02 | Temporary Error – No input of parameters C1/C2. PCB not configured. |
H.02 – .03 | Temporary error- Incorrect configuration settings C1/C2. |
H.02 – .04 | Temporary error- Parameter fault. Incorrect parameters. |
H.02 – .06 | Temporary error – System water pressure / Water leak on boiler/ Water leak on system. |
H.03 -.00 | Temporary error with Communication fault / NTC flue sensor error. Sensor not connected or has a bad connection |
H.03 – .01 | Communication error with the HMI PCB |
H.03 – .02 | Flame error – No flame during operation. |
E.00 – .04 | Return temperature sensor open-circuit. Sensor not or badly connected. |
E.00 – .05 | Return temperature sensor short-circuit. Sensor not connected or badly connected |
E.01 – .02 | Temperature measured by return sensor greater than flow sensor. |
E.01 – .04 | Loss of flame detected 5 times in 24 hours (With burner on). |
E.01 – .11 | Incorrect fan speed. External draught over the boiler. Defective gas/air unit. |
E.01 – .12 | Requires Reset – Temperature measured by return sensor greater than flow temperature. |
E.01 – .17 | Requires Reset – No circulation. Sensor fault either not connected or has a bad connection |
E.01 – .20 | Maximum flue gas temperature reached. No circulation. Sensor fault. |
E.02 – .00 | Boiler reset – Reset button has been pressed. |
E.02 – .07 | No or low system water pressure. system pressure less than 0.5bar |
E.02 – .16 | CSU time-out. PCB damage. |
E.02 – .17 | loss of communication between gas valve and boiler PCB. Fault in air/gas unit. |
E.02 – .19 | Jumper 1 changed. Check position of jumper 1. |
E.02 – .20 | Jumper 2 changed. Check position of jumper 2. |
E.02 – .21 | Jumper 3 changed. Check position of jumper 3. |
E.02 – .47 | Wiring to external device error. |
E.02 – .48 | Configuration to external device unsuccessful. Check pairing to external. |
E.04 – .00 | Gas valve error. Gas valve not detected. |
E.04 – .01 | Flow temperature sensor short-circuited. Sensor not or badly connected. Bad connection. Sensor fault. |
E.04 – .02 | Permanent Fault – Flow temperature sensor open-circuited. Sensor not or badly connected. Bad connection. Sensor fault. |
E.04 – .03 | Permanent Fault – Critical flow temperature reached. Non-existent or insufficient circulation. |
E.04 – .04 | Permanent Fault – Flue temperature sensor short-circuited. Sensor not or badly connected. Bad connection. Sensor fault. |
E.04 – .05 | Permanent Fault – Flue temperature sensor open-circuited. Sensor not or badly connected. Bad connection. Sensor fault. |
E.04 – .06 | Permanent Fault – Critical flue gas temperature value reached. No circulation. Sensor fault. |
E.04 – .08 | Permanent Fault – Maximum safe temperature value reached. (Safety thermostat open-circuited). No circulation. Sensor not or badly connected. Bad connection. Sensor fault. |
E.04 – .10 | Failure to light (could be gas supply issue). |
E.04 – .12 | Permanent Fault – False flame signal. Short-term fluctuation of the mains. Ionization current present even though there is no flame. The burner remains very hot (CO2 too high). Defective gas/air unit. |
E.04 – .13 | Permanent Fault – Fan rotor blocked. Fan seized. Wiring to fan damaged. |
E.04 – .17 | Permanent Fault – Problem with gas valve. Defective gas/air unit. |
Baxi 600 Combi Gas Boiler Error Codes
Listed below are some of the fault codes that could appear on your Baxi 600 combi gas boiler.
Fault Code | Possible Cause |
---|---|
E09 | Gas valve connection cable. |
E10 | External probe fault. |
E12 | Differential water flow switch fault (still open). |
E13 | Differential water flow switch fault (still closed). |
E15 | Gas valve command fault. |
E20 | Central heating NTC fault. |
E28 | Flue NTC fault. |
E40 | Central heating return NTC fault. |
E50 | DHW NTC sensor fault (tank boiler) (s.c.) OR DHW NTC sensor fault (tank boiler) (o.c.). |
E83/E84/E85/E86/E87 | No communication. |
E109 | Pre-circulation fault. |
E110 | i) Boiler max temperature exceeded for gradient (probable pump jammed or air in the circuit). OR ii) Boiler max temperature exceeded for overtemperature (probable pump jammed or air in the circuit). OR iii) Safety thermostat sensor tripped. |
E118 | Primary system water pressure too low (< 0.5 bar). |
E125 | Circulation fault (primary). |
E128 | Frequent flame failure (12 times). |
E129 | Safety error for frequently loss of flame with max correction during the ignition during Calibration Function. |
E130 | Flue thermostat sensor tripped (lockout). |
E133 | Failure to light (could be a gas supply issue). |
E134 | Elapsed time gas valve open without gas (short request in a short period) |
E135 | Interruption of gas supply (internal error). |
E154 | Flow/return sensor temperature test. |
E160 | Fan or fan wiring fault. |
E163 | Domestic Hot Water NTC sensor fault (s.c.) OR Domestic Hot Water NTC sensor fault (o.c.). |
E270 | Circulation fault (dry fire). |
E317 | Wrong power supply electrical frequency (Hz). |
E321 | Hot water NTC fault. |
E384 | False flame. |
E385 | Under voltage. |
E430 | Water pressure temporary test. |
E430 + Flame ‘crossed’ | Water pressure test failed. |
Error Code E133 and E28
If you’re seeing either of these two error codes on your Baxi boiler, this is due to your condensate pipe being frozen. In the cold winter months this can happen easily as the condensate pipe runs outside. You can fix this issue by thawing out the pipe (if you feel confident to)
Evelyn Moran says
How do u rectify the error e134 on my boiler
Lee Combe says
Hi Evelyn, thanks for your comment. This sounds like the PCB needs changed on it. if you need any further information, please email us on [email protected]
review says
This is really helpful, thanks.