Worcester Bosch boilers are some of the most reliable residential boilers on the market today.
If you are experiencing some difficulty with your boiler and displaying error codes then this guide may be helpful to you.
Should you need professional help with your broken boiler, then simply use one of our enquiry forms and we will connect you with the best heating engineers local to you.
Related content:
Emergency 24 Hour Plumbing Service
Worcester Bosch Boiler Error Codes
Listed below are some error codes that could appear on your Worcester Bosch Boiler:
Fault Description | System Behaviour |
---|---|
Locking error | The boiler display will flash a warning triangle and fault code. At the same time a (static) cause code will also be displayed. Manual intervention (Pressing the reset button on the boiler fascia) is required following clearance of the fault. |
Blocking error | The boiler will stop operating with no fault data displayed. The cause code, in the info menu, is accessed by pressing the spanner/return button. The condition will clear automatically when the associated fault clears e.g. waiting for an area to cool. In some cases a blocking error has a defined time duration prior to changing to a locking condition. |
Fault error | Alpha numeric code indicating the fault group |
Cause error | Three digit number. During a blocking error (or normal operating status) it is not displayed, but accessed in the info menu via the spanner/return button. During a locking error the cause code flashes on the display. |
Maintenance codes | These are displayed with the letter H followed by a number. The code advises of a situation that will need some attention but is not a fault that will stop the boiler from functioning. Some of the common ones are listed: H11 Hot water outlet sensor defect, hot water can still be delivered but with less control H13 A time has been set in the Service interval function i.e. 1 to 72 months and that time has expired. Menu 2.5F allows this feature to be set (1 to 72), a 0 will disable this function. |
Worcester Bosch Locking Error Codes
Listed below are some error codes that could appear on your Worcester Bosch Boiler:
Fault Code | Possible Cause |
---|---|
9A | Incorrect HCM fitted |
9U | Problem with the code plug (faulty or not connected) |
B7 | Replace control board |
C6 | Running too fast / Running too slow |
C7 | Fan not running / Fan not running or airflow blocked |
D1 | Sensor wet or damaged (the boiler will block for 300 seconds before this condition) |
D1 | Sensor disconnected or damaged (the boiler will block for 300 seconds before this condition) |
D1 | Boiler overheat |
E2 | Flow sensor shorted or damaged |
E2 | Flow sensor disconnected or damaged |
E5 | Primary flow sensor overheated |
E9 | The main heat exchanger has overheated. Maximum temperature 105°C |
E9 | Maximum temperature sensor on the main heat exchanger has failed |
E9 | Maximum temperature sensor on the main heat exchanger has not been recognised |
E9 | Flue gas thermostat overheat |
EA | Failure of four ignition attempts. The boiler waits 30 seconds before another attempt is made |
EA | An established flame has been extinguished. This could be caused by: moisture in the sump, due to a blocked sump/condensate trap. a strong wind into the flue |
EA | Gas valve coil disconnected |
EA | Flame not established during the first 4 seconds ignition period |
EA | There is an error where the pump is not detecting water – check pressure gauge and repressurise to 1 bar. |
Worcester Bosch Blocking Error Codes
Listed below are some error codes that could appear on your Worcester Bosch boiler.
Fault Code | Possible Cause |
---|---|
A1 | Little or no water in the system – check pressure gauge and repressurise to 1 bar. |
C1 | Fan has stopped |
EA | No flame is detected. The boiler will block during 4 attempts before going to Locking fault |
EF | The boiler is operating at minimum burner load and there is a greater than 18°C Flow & Return temperature difference |
No Code | Air lock or reduced water content – check pressure gauge and repressurise to 1 bar |
260 | Sensor disconnected or no water content – check pressure gauge and repressurise to 1 bar |
Boiler Repair Quote
If you are having problems with your Ideal Logic Max Plus Combi Boiler and have the above error codes appearing then give us a call today.
We offer a 24/7 emergency call out service to cater for our customers needs and can offer you a free quote if there are any parts needed.
Get in touch with us today.
David Rossiter says
I ke
ep getting L1 on my Worcester condensing boiler what does it mean ps the 0001 are numbers in my email
Lee Combe says
Hi David,
This is lack of water in the system.
Lauren
Barry Robinson says
Hi what is fault code ER on worc 37 –reset and it last for some days and then locks out again showing fault code ER –any idea’s